Identify the item
Include the full model, manufacturer P/N, revision and quantity.
Product image unavailable
Request images of the exact model and configuration with your quote.Supermicro / Enterprise Server
Manufacturer P/N: SYS-F629P3-RC1B
Supermicro SYS-F629P3-RC1B. Cores: Up to 28 Cores; Memory capacity: 12 DIMM slots Up to 3TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM ††. Request pricing and configuration review.
Pricing, availability, condition, included options and warranty are confirmed in your quotation.
Technical overview
Use the complete part number when reviewing options and system requirements.
| Cores | Up to 28 Cores |
|---|---|
| Memory capacity | 12 DIMM slots Up to 3TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| Memory type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| Lan | SIOM flexible Network card 1 RJ45 Dedicated IPMI LAN port |
| Form factor | 4U Rackmount |
| Width | 17.63" (448mm) |
| Height | 6.96" (177mm) |
| Depth | 29" (737mm) |
| Manufacturer | Supermicro |
| System model | SYS-F629P3-RC1B |
| SYS-F629P3-RC1B | SuperServer F629P3-RC1B ( Black ) |
| CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-165W with IVR |
| Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R). Extended thermal solutions may be required to support CPUs higher than 165W TDP, please contact Supermicro Technical Support for additional information. |
| Chipset | Intel® C621 chipset |
| SAS | SAS3 (12Gbps) via Broadcom 3108 HW RAID Firmware Download |
| Network Controllers | Flexible networking via SIOM |
| IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| Graphics | ASPEED AST2500 BMC |
| NVMe | 2 NVMe U.2 optional |
| USB | 2 USB 3.0 ports (rear) |
| VGA | 1 VGA port |
| BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS |
| Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SuperDoctor® 5 Watch Dog |
| Power Configurations | ACPI Power Management |
| FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Model | CSE-F424AS2-R1K23BP |
| Package | 28.3" (W) x 15.0" (H) x 42.4" (D) |
| Weight | Net Weight: 150 lbs (68.04 kg) Gross Weight: 200 lbs (90.71 kg) |
| Available Colors | Black |
| Buttons | Power On/Off button UID button |
| LEDs | Power status LED Hard drive activity LED Network activity LEDs Information LED (UID, Fan failure, Overheat) |
| PCI-Express | 1 PCI-E 3.0 x16 (Low-profile) 1 PCI-E 3.0 x16 (SIOM) |
| Hot-swap | 8 Hot-swap 3.5" SAS3/SATA3 or 6 Hot-swap 3.5" SAS3/SATA3 + 2 optional NVMe U.2 |
| M.2 | M.2 Interface: PCI-E 3.0 x4 M.2 Form Factor: 2260, 2280, 22110 M.2 Key: M-Key |
| Fans | 2x 8cm 14 RPM middle fans |
| Total Output Power | 1000W/1200W |
| Dimension (W x H x L) | 76 x 40 x 336 mm |
| Input | 100-127Vac / 15-12A / 50-60Hz 200-240Vac / 8.5-7A / 50-60Hz 200-240Vdc / 8.5-7A (for CCC only) |
| +12V | Max: 83A / Min: 0A (100-127Vac) Max: 100A / Min: 0A (200-240Vac) Max: 100A / Min: 0A (200-240Vdc) |
| +5Vsb | Max: 4A / Min: 0A |
| Output Type | 19 Pairs Gold Finger Connector |
| Certification | Titanium Level [ Test Report ] |
| RoHS | RoHS Compliant |
| Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
Model & application details
Supermicro · Enterprise Server
SYS-F629P3-RC1B — Cores: Up to 28 Cores; Memory Capacity: 12 DIMM slots Up to 3TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM ††; Memory Type: 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM; Form Factor: 4U Rackmount.
Quotation on request · Exact BOM and availability confirmed before ordering.
Manufacturer specifications
This model appears in the manufacturer system matrix. Confirm current orderability, condition and the supplied configuration with your quotation.
| Manufacturer | Supermicro |
|---|---|
| System model | SYS-F629P3-RC1B |
| SYS-F629P3-RC1B | SuperServer F629P3-RC1B ( Black ) |
| CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-165W with IVR |
| Cores | Up to 28 Cores |
| Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R). Extended thermal solutions may be required to support CPUs higher than 165W TDP, please contact Supermicro Technical Support for additional information. |
| Memory Capacity | 12 DIMM slots Up to 3TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Chipset | Intel® C621 chipset |
| SAS | SAS3 (12Gbps) via Broadcom 3108 HW RAID Firmware Download |
| Network Controllers | Flexible networking via SIOM |
| IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| Graphics | ASPEED AST2500 BMC |
| SAS | 8 SAS3 (12Gbps) ports |
| NVMe | 2 NVMe U.2 optional |
| LAN | SIOM flexible Network card 1 RJ45 Dedicated IPMI LAN port |
| USB | 2 USB 3.0 ports (rear) |
| VGA | 1 VGA port |
| BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS |
| Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SuperDoctor® 5 Watch Dog |
| Power Configurations | ACPI Power Management |
| CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Form Factor | 4U Rackmount |
| Model | CSE-F424AS2-R1K23BP |
| Width | 17.63" (448mm) |
| Height | 6.96" (177mm) |
| Depth | 29" (737mm) |
| Package | 28.3" (W) x 15.0" (H) x 42.4" (D) |
| Weight | Net Weight: 150 lbs (68.04 kg) Gross Weight: 200 lbs (90.71 kg) |
| Available Colors | Black |
| Buttons | Power On/Off button UID button |
| LEDs | Power status LED Hard drive activity LED Network activity LEDs Information LED (UID, Fan failure, Overheat) |
| PCI-Express | 1 PCI-E 3.0 x16 (Low-profile) 1 PCI-E 3.0 x16 (SIOM) |
| Hot-swap | 8 Hot-swap 3.5" SAS3/SATA3 or 6 Hot-swap 3.5" SAS3/SATA3 + 2 optional NVMe U.2 |
| M.2 | M.2 Interface: PCI-E 3.0 x4 M.2 Form Factor: 2260, 2280, 22110 M.2 Key: M-Key |
| Fans | 2x 8cm 14 RPM middle fans |
| Total Output Power | 1000W/1200W |
| Dimension (W x H x L) | 76 x 40 x 336 mm |
| Input | 100-127Vac / 15-12A / 50-60Hz 200-240Vac / 8.5-7A / 50-60Hz 200-240Vdc / 8.5-7A (for CCC only) |
| +12V | Max: 83A / Min: 0A (100-127Vac) Max: 100A / Min: 0A (200-240Vac) Max: 100A / Min: 0A (200-240Vdc) |
| +5Vsb | Max: 4A / Min: 0A |
| Output Type | 19 Pairs Gold Finger Connector |
| Certification | Titanium Level [ Test Report ] |
| RoHS | RoHS Compliant |
| Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
Model selection & order planning
Supermicro SYS-F629P3-RC1B
These are other catalog models in this category. Review each model separately; a shared category does not establish interchangeability.
Prepare your enquiry
Include the full model, manufacturer P/N, revision and quantity.
Tell us the host model, generation, installed configuration and required supporting hardware.
Specify condition, testing requirements, destination and requested delivery date.