Servers, storage, networking and replacement parts. sales@star-networking.com

TP-Link / Ethernet Switch

TP-Link S5500-24GP4XF

Manufacturer P/N: S5500-24GP4XF

TP-Link S5500-24GP4XF ethernet switch. Interface: • 24× 10/100/1000 Mbps RJ45 Ports (all support PoE+) • 4× 10G SFP+ Slots • 1× RJ45 Console Port • 1× Micro-USB Console Port; Fan Quantity: 2; Power Supply: 100~240VAC, 50/60Hz. Compare configuration and request a hardware quote.

Documented hardware version
V1; match the hardware revision before ordering
Interface
• 24× 10/100/1000 Mbps RJ45 Ports (all support PoE+) • 4× 10G SFP+ Slots • 1× RJ45 Console Port • 1× Micro-USB Console Port
Fan Quantity
2
Power Supply
100~240VAC, 50/60Hz

Price on request

Contact us to confirm availability. Final price, shipping and taxes are confirmed before payment.

Pricing, availability, condition, included options and warranty are confirmed in your quotation.

Help choosing compatible hardwareWorldwide delivery

CONNECTIONS & COMPATIBILITY

Network connections and supported equipment

Check the protocol and port requirements of the equipment you intend to connect. Ethernet, Fibre Channel, InfiniBand and carrier interfaces are not interchangeable.

CONNECTS TOClients, servers or access links
S5500-24GP4XFEthernet Switch
USED FORConnected network equipment
Connection and installation requirements
  • Port type, line rate, optics, reach and software license
  • Peer platform support, resiliency and management design

Browse the product categories above for related equipment. Confirm compatibility with your full configuration before ordering.

Technical overview

Technical specifications

Use the complete part number when reviewing options and system requirements.

S5500-24GP4XF specifications
ManufacturerTP-Link
Manufacturer part numberS5500-24GP4XF
Product familyBusiness ethernet switchs
Documented hardware versionV1; match the hardware revision before ordering
Interface• 24× 10/100/1000 Mbps RJ45 Ports (all support PoE+) • 4× 10G SFP+ Slots • 1× RJ45 Console Port • 1× Micro-USB Console Port
Fan Quantity2
Power Supply100~240VAC, 50/60Hz
Dimensions ( W x D x H )17.3 × 13.0 × 1.7 in (440 × 330 × 44 mm)
MountingRackmountable
Max. Power Consumption• 30.43 W (110V/60Hz) (no PD connected) • 486.2 W (110V/60Hz) (with 384 W PD connected)
Max. Heat Dissipation• 103.77 BTU/hr (110 V/60 Hz) (no PD connected) • 1658.78 BTU/hr (110 V/60 Hz) (with 384 W PD connected)
Packet Buffer Memory12 Mbit
Jumbo Frame9 KB
Switching Capacity128 Gbps
Packet Forwarding Rate95.23 Mpps
MAC Address Table16 K
Omada AppYes, through Omada Pro Controller
Centralized Management• Omada Pro Cloud-Based Controller • Omada Pro Software Controller
Cloud AccessYes, through Omada Pro Controller
Zero-Touch ProvisioningYes. Requiring the use of Omada Pro Cloud-Based Controller
System RequirementsMicrosoft® Windows® XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Quality of Service• 8 priority queues • 802.1p CoS/DSCP priority • Queue scheduling - SP (Strict Priority) - WRR (Weighted Round Robin) - SP+WRR • Bandwidth Control - Port/Flow based Rating Limiting • Smoother Performance • Action for Flows - QoS Remark (802.1P Remark, DSCP Remark)
L3 Features• 16 IPv4/IPv6 Interfaces • Static Routing - 48 static routes • Static ARP - 128 static entries • 512 ARP Entries • Proxy ARP • Gratuitous ARP • DHCP Server • DHCP Relay • DHCP L2 Relay
L2 and L2+ Features• Link Aggregation - Static link aggregation - 802.3ad LACP - Up to 8 aggregation groups and up to 8 ports per group • Spanning Tree Protocol - 802.1d STP - 802.1w RSTP - 802.1s MSTP - STP Security: TC Protect, BPDU Filter, BPDU Protect, Root Protect, Loop Protect • Loopback Detection - Port-based - VLAN based • Flow Control - 802.3x Flow Control - HOL Blocking Prevention • Mirroring - Port Mirroring - CPU Mirroring - One-to-One - Many-to-One - Tx/Rx/Both
L2 Multicast• Supports 1000 (IPv4, IPv6) IGMP groups • IGMP Snooping - IGMP v1/v2/v3 Snooping - Fast Leave - IGMP Snooping Querier - IGMP Authentication • IGMP Authentication • MVR • MLD Snooping - MLD v1/v2 Snooping - Fast Leave - MLD Snooping Querier - Static Group Config - Limited IP Multicast • Multicast Filtering: 256 profiles and 16 entries per profile
VLAN• VLAN Group - Max. 4K VLAN Groups • 802.1Q tag VLAN • MAC VLAN: 30 Entries • Protocol VLAN: Protocol Template 16, Protocol VLAN 16 • Private VLAN • GVRP • Voice VLAN • VLAN VPN (QinQ) - VLAN Mapping - VLAN Replace • OUI-Based VLAN
Access Control List• MAC ACL - Source MAC - Destination MAC - VLAN ID - User Priority - Ether Type • IP ACL - Source IP - Destination IP - Fragment - IP Protocol - TCP Flag - TCP/UDP Port - DSCP/IP TOS - User Priority • Combined ACL • IPv6 ACL • Policy - Mirroring - Redirect - Rate Limit - QoS Remark • ACL apply to Port/VLAN • Time-based ACL
Security• IP-MAC-Port Binding - 512 Entries - DHCP Snooping - ARP Inspection - IPv4 Source Guard: 100 Entries • IPv6-MAC-Port Binding - 512 Entries - DHCPv6 Snooping - ND Detection - ND Snooping - IPv6 Source Guard: 100 Entries • DoS Defend • DHCP Filter • Static/Dynamic Port Security - Up to 64 MAC addresses per port • Broadcast/Multicast/Unicast Storm Control - kbps/ratio/pps control mode • 802.1X - Port base authentication - Mac base authentication - VLAN Assignment - MAB - Guest VLAN - Support RADIUS authentication and accountability • AAA (including TACACS+) • Port Isolation • Secure web management through HTTPS with SSLv3/TLS 1.2 • Secure Command Line Interface (CLI) management with SSHv1/SSHv2 • IP/Port/MAC-based access control
IPv6• IPv6 Dual IPv4/IPv6 • Multicast Listener Discovery (MLD) Snooping • IPv6 ACL • IPv6 Interface • Static IPv6 Routing • IPv6 neighbor discovery (ND) • Path maximum transmission unit (MTU) discovery • Internet Control Message Protocol (ICMP) version 6 • TCPv6/UDPv6 • IPv6 applications - DHCPv6 Client - Ping6 - Tracert6 - Telnet (v6) - IPv6 SNMP - IPv6 SSH - IPv6 SSL - Http/Https - IPv6 TFTP
MIBs• MIB II (RFC1213) • Interface MIB (RFC2233) • Ethernet Interface MIB (RFC1643) • Bridge MIB (RFC1493) • P/Q-Bridge MIB (RFC2674) • RMON MIB (RFC2819) • RMON2 MIB (RFC2021) • RADIUS Accounting Client MIB (RFC2620) • RADIUS Authentication Client MIB (RFC2618) • Remote Ping, Traceroute MIB (RFC2925) • Support TP-Link Private MIB
Management Features• Web-based GUI • Command Line Interface (CLI) through console port, telnet • SNMPv1/v2c/v3 - Trap/Inform - RMON (1, 2, 3, 9 groups) • SDM Template • DHCP/BOOTP Client • 802.1ab LLDP/LLDP-MED • DHCP Auto Install • Dual Image, Dual Configuration • CPU Monitoring • Cable Diagnostics • EEE • Password Recovery • SNTP • System Log • Remote Packet Capture
Environment• Operating Temperature: 0–45 ℃ (32–113 ℉); • Storage Temperature: -40–70 ℃ (-40–158 ℉) • Operating Humidity: 10–90% RH non-condensing • Storage Humidity: 5–90% RH non-condensing

PRODUCT DETAILS

Features and applications

S5500-24GP4XF at a glance

TP-Link S5500-24GP4XF is an ethernet switch in the Business ethernet switchs range. Use the model code when matching your deployment or replacement requirement.

  • Interface: • 24× 10/100/1000 Mbps RJ45 Ports (all support PoE+) • 4× 10G SFP+ Slots • 1× RJ45 Console Port • 1× Micro-USB Console Port
  • Fan Quantity: 2
  • Power Supply: 100~240VAC, 50/60Hz

Configuration and installation

Plan the access-port count, uplink media and aggregate PoE load together. Verify the exact power-supply configuration, stacking components and optics before confirming the order.

Confirm hardware revision and included items in the quotation. A firmware-dependent feature or licensed capability must be checked against the actual configuration.

Related business Ethernet switches

Ordering questions

What should I include in an enquiry?

Send S5500-24GP4XF with quantity, destination, required condition and any installation constraints. List power, optics or mounting accessories separately when required.

Are accessories and support included?

Inclusions depend on the exact ordering configuration. We confirm the supplied hardware, accessories and applicable commercial terms in writing.

Browse TP-Link equipment · Network equipment · Request a matched quotation

Prepare your enquiry

Ordering and delivery

Model and quantity

Include the full model, manufacturer P/N, revision and quantity.

Your existing equipment

Tell us the host model, generation, installed configuration and required supporting hardware.

Delivery requirements

Specify condition, testing requirements, destination and requested delivery date.