SYS-1019P-FRDN2TCompute platform · Category illustrationAsk for photos of the exact model and configuration.
Use the full model, manufacturer part number and revision. Your quotation will list the condition and included components.
Build around your workload
Supermicro SYS-1019P-FRDN2T Enterprise Server
P/N SYS-1019P-FRDN2T
Supermicro SYS-1019P-FRDN2T enterprise server, manufacturer order code SYS-1019P-FRDN2T. Review the documented processor, memory, storage, expansion, networking, cooling and power requirements for this exact system SKU.
Memory Capacity
6 DIMM slots Up to 1.5TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM
Form Factor
1U Rackmount
Memory Type
2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
Manufacturer model
SYS-1019P-FRDN2T
Request pricingQuoted to your requirements
Tell us the configuration, quantity and destination. Your quotation will show availability, condition, warranty and delivery terms.
Use the full part number when comparing options or asking about system fit.
51 of 51 specifications
SYS-1019P-FRDN2T · All specifications
Manufacturer model
SYS-1019P-FRDN2T
Ordering P/N
SYS-1019P-FRDN2T
Product type
Manufacturer system order code; listed processor, memory, storage, expansion, networking, cooling and power details describe platform capabilities or limits unless the source explicitly states installed components
Manufacturer category
Server System
Motherboard
Super X11SPW-TF
Processor/Cache — CPU
Single Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ Support CPU TDP 70-205W *
Cores
Up to 28 Cores
Processor/Cache — Note 1
* Certain high frequency optimized CPU are not supported, such as Intel Gold 6250 and 6256. Please contact Supermicro Technical Support for additional information.
Processor/Cache — Note 2
‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R)
Memory Capacity
6 DIMM slots Up to 1.5TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM
Memory Type
2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
System Memory — Note
† 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info.
Chipset
Intel® C622 chipset
On-Board Devices — SATA
SATA3 (6Gbps)
Network Controllers
Dual 10GBase-T LAN with Intel® X722 + X557
IPMI
Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
On-Board Devices — Video
ASPEED AST2500 BMC
Input / Output — SATA
2 SATA3 (6Gbps) ports
LAN
2 RJ45 10GBase-T LAN ports 1 RJ45 dedicated IPMI LAN port
USB
2 USB 3.0 ports 2 USB 2.0 ports
Input / Output — Video
1 VGA port
Serial Port / Header
1 COM port
SuperDOM
Ports default connect to hard drive bays
BIOS Type
AMI 32Mb SPI Flash ROM
Management software listed for this platform
Intel® Node Manager IPMI 2.0 KVM with dedicated LAN NMI SPM , SUM SuperDoctor® 5 Watch Dog
Power Configurations
ACPI / APM Power Management
PC Health Monitoring — CPU
Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator
FAN
Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors
Temperature
Monitoring for CPU and chassis environment Thermal Control for fan connectors
Form Factor
1U Rackmount
Model
CSE-515M-R601
Height
1.7" (43mm)
Width
17.2" (437mm)
Depth
15.7" (399mm)
Package
8" (H) x 27" (W) x 24" (D)
Weight
Gross Weight: 29 lbs (13.15 kg) Net Weight: 18 lbs (8.16 kg)
Available Colors
Black
Buttons
Power On/Off button System Reset button
LEDs
Power LED Hard drive activity LED Network activity LEDs System Information LED Information LED (temp., status)
PCI-Express
2 PCI-E 3.0 x16 (FHFL) slots
M.2
1x M.2 Interface: PCI-E 3.0 x4 and SATA Form Factor: 2280, 22110 Key: M-Key Double Height Connector
Fixed
2 Fixed 2.5" Drive Bays
Fans
5x 40x56 Hot-Swappable Fan Trays
Total Output Power
600W: -44Vdc to -65Vdc
Dimension (W x H x L)
54.5 x 40 x 220 mm
DC Input
-44Vdc to -65Vdc / 18 - 10A
+12V
Max: 50A / Min: 0A
+5V sb
Max: 3A / Min: 0A
Output Type
Gold Finger Connector Mating with Molex 45984-4343
RoHS
RoHS Compliant
Environmental Spec.
Operating Temperature: 10°C ~ 40°C (50°F ~ 104°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing)
02
HOW THIS PRODUCT FITS YOUR SYSTEM
See where it fits in your system
Choose how you plan to use this product.
Virtualization
Processor, memory and drive configuration
Match the processor generation, socket population and required heatsink.
Check the installed modules, supported type and population rules.
Use this checklist to describe the change. The host system and full configuration determine which parts will fit.
03
YOUR QUOTE REQUEST
Tell us what you need
Add the quantity, options and installation details you want us to quote.
Confirm the exact manufacturer part number, host compatibility and included components. Optional software is quoted separately only when requested.
04
SUPPORT & REPLACEMENT
Plan for support and future replacement
Check support dates, replacement options and whether continued use still makes sense.
Support dates
We do not have confirmed sales and support dates for this part number.
Send us the full SYS-1019P-FRDN2T order code, software release and support details before planning long-term use.
Ask us to check the current sales and support status
Choosing a replacement
Products with similar names or connectors may still be incompatible. Compare the full specifications, installed system and software requirements.
Compare related products These products may be related, but we have not confirmed them as replacements.What should I compare?
Physical fit, connectors and power
Capacity and required performance
Software, firmware and feature support
Licensing, service coverage and data and configuration migration
USING HARDWARE RESPONSIBLY
Maintain, redeploy or replace
Consider repairability, remaining support and actual operating demand. Extending service life is useful only when the equipment still meets your security and reliability requirements.
MaintainCheck parts, firmware and service options.
RedeployMatch a suitable role and securely erase any retained data.
Retire responsiblyUse documented data removal and an appropriate electronics recycler.
Compare operating energy
Use measured average input power for the same workload. PSU ratings and processor TDP are different from total system power.
Energy difference = (current W − proposed W) × hours × units ÷ 1,000. Excludes cooling, embodied emissions and purchase costs.
CONNECTION DETAILS
Network and storage connections
Choose the host adapters around the workload and the storage protocol. A server NIC, Fibre Channel HBA and SAS HBA serve different connections.
CONNECTS TOUsers & application traffic
→
SYS-1019P-FRDN2TEnterprise Server
→
USED FORNetwork and storage services
What to check before installation
Qualified adapters, slots, drivers and optics
Network paths, storage protocol and operating system
Browse the categories above for related equipment, then send us the full configuration so we can check the fit.
PRODUCT DETAILS
Features and applications
SYS-1019P-FRDN2T system ordering
Supermicro SYS-1019P-FRDN2T enterprise server, manufacturer order code SYS-1019P-FRDN2T. Review the documented processor, memory, storage, expansion, networking, cooling and power requirements for this exact system SKU.
The listed processor, memory, storage, expansion, networking, cooling and power values are manufacturer platform capabilities or limits. Optional and supported components are not installed unless the exact source row explicitly states inclusion.
Software and operating systems shown are platform listings; licenses and subscriptions are not assumed to be included. The saved manufacturer Product SKUs section identifies this order code as Discontinued SKU (EOL). Confirm the exact revision, regional order code, configuration and current supply before ordering.
Before you request a quote
Ordering and delivery
Model and quantity
Include the full model, manufacturer P/N, revision and quantity.
Your existing equipment
Tell us the host model, generation, installed configuration and required supporting hardware.
Delivery requirements
Specify condition, testing requirements, destination and requested delivery date.